1) What PRESSURE should my COMPRESSOR SHUT OFF?

  • The operating range is 100psi to 135psi (plus or minus 10psi for gauge variation)

2) How LONG should it take to FILL the AIR TANK?

  • Small Tank (5"x7") 2.5 to 3 minutes from empty
  • Large Tank (5"x14") 3.5 to 4 minutes from empty

****Compressor should not be allowed to run for more than 7 minutes "without" a minimum of 30 minutes cool down period. (depending on ambient temperature)

3) My COMPRESSOR will not SHUT OFF?

  • Check Pressure Gauge (if equipped) for pressure build up. If the gauge shows no reading then, review installation instructions for proper assembly
  • Check for air leaks - All fittings, hoses, outlet at solenoid, tank seam, mounting studs, and welds
  • Solenoids can easily be checked by putting a small balloon or baggie over outlet and looking to see if it fills up with air
  • Check for debris in Check Valve/ Solenoid, also check for proper orientation of check valve.

4) Where can I get REPLACEMENT PARTS?

  • Please visit our distributors section of the web page

5) How LONG can I expect WARRANTY EVALUATION to take?

  • Average 2 week turn around (longer during holidays)

If you are experiencing problems, please refer to our Compressor Troubleshooting Guide for diagnostic assistance .